HMC: 9.123.xx.xx labuser/passw0rd (1 P720 is being managed 。 PowerVC 不支持 Power5 ,必须是 Power6 以上。 HMC Model CR5 or later , HMC 版本最低要求是 7.7.8.0)
V7000: 9.123.xx.xx labuser/passw0rd
SAN Switch: 9.123.xx.xx labuser/passw0rd (如果需要测试 PowerVC Standard Edition , SAN Switch 需要是 Brocade 16Gb 、 Firmware 6.4 或以上,除了 SAN24B-5 和 SAN48B-5 , IBM Flex System FC5022 16 GB Scalable Switch 也是 Brocade 16Gb 的)
pLinux LPAR for PowerVC installation: 9.123.xx.xx root/passw0rd
Software Package is under /tmp/software
OS Image Template : SN06B7F5T with LPAR Name: template
如果要测试 Shared Storage Pool , HMC 需要 v8.8.1.0 或以上
如果要测试 PowerKVM ,就需要 POWER8 , HMC v8.8.1.0
Installation
mount –o loop /dev/sr0 /mnt/cdrom
create /etc/yum.repos.d/local.repo file, including following contents
[local]
name=local
baseurl=file:///mnt/cdrom/Server
gpgcheck=0
enabled=1
CentOS 6.5 也是可行的,但是 PowerVC 的 Install 和 Update 脚本都会报错退出,需要绕过去
selinux: /etc/selinux/config -> selinux=disabled/permissive 修改这个 selinux 配置后需要重启操作系统?
/etc/hosts: 9.123.xx.x lab0x.cn.ibm.com lab0x
Created the SAN fabric and disabled the physically disconnected Fibre Channel ports (in the "Configuration" menu).
Created the static network to be used for to-be-deployed LPARs
User Scenarios
Functionality | Description | Notes | |
1 | Validate Environment | Run the environment validation tool to verify the resources being managed are operating properly. | |
2 | View Host / HMC Details | Navigate to the hosts panel and drill-down on the hosts or select the HMC connections tab at the top and view the respective details. | |
3 | Deploy Virtual Appliance | Select a pre-populated RHEL 6.4 (RHEL-64) or AIX 7.1 (AIX-71) virtual appliance to deploy within PowerVC. | Static IPs that can be used for deploy: 172.26.43.25-172.26.43.126 |
4 | View Virtual Machine Details | Navigate to the virtual machine panel and drill down on the properties of the newly created virtual machine instance. | |
5 | Create a Storage Volume | Navigate to the storage volume panel and create a new storage volume that can be attached to a running VM instance. | |
6 | Attach Storage Volume to VM | Navigate to newly created storage volume and attach to VM previously created. | |
7 | Resize VM | Select the newly created VM and resize the virtual memory and CPU as desired. | |
8 | Live Migration (Partition Mobility) | Select the newly created VM and select the migrate button to live migrate the VM to the other host. | |
9 | Capture | Select the VM and capture as a new image within the repository. | * For purposes of the hosted environment you can use the VM already prepared for capture (VM2Capture). For more information on the capture process please reference the PowerVC documentation. |
HMC and VIOS fixes useful for PowerVC environments
Component | Base Code | Fixes | Release Date |
Hardware Management Console (HMC) | 7.7.8 | MH01388 Mandatory: Required for V7.7.8 | Dec 6, 2013 |
MH01403 Recommended: Fixed an issue where, after an upgrade to V7R7.8.0, no user profile can login to the GUI and only the user id hscroot can login using ssh. | Jan 21, 2014 | ||
MH01397 Recommended. All previous PowerVC-related patches for V7.7.8 | Mar 10, 2014 | ||
7.7.8 SP1 | MH01431 Mandatory: Fixed a problem with Service Pack 1 where the cumulative fixes for IBM PowerVC were not installed. | May 15, 2014 | |
8.1.0 | MH01421 Mandatory: Required for V8.1.0 | ||
Virtual I/O Server (VIOS) | 2.2.3.1 (FP27) | IV52899m1a Required iFix for PowerVC and VIOS Usability Support | Dec 12, 2013 |
IV54776m1a Required iFix for LPM and for PowerVC and VIOS Usability Support | Feb 21, 2014 | ||
IV53197m1b Required iFix for LPM and for PowerVC and VIOS Usability Support Includes IV52899, IV53197, IV53505, IV54776 | Mar 31, 2014 | ||
2.2.3.3 (FP27-SP3) | IV56366 Required iFix for PowerVC 1.2.1 | June 6, 2014 |